Skip to main content Skip to main content

Bussmann Fusetron™ FRS-R-8 Current Limiting Renewable Time Delay Fuse, 8 A, 600 VAC/300 VDC, 200 kA Interrupt, RK5 Class, Cylindrical Body

IDW_IMAGE_2bcff10a77269f11f2df35fc029bc65ee1d3e622826fe5db712cba24f97421ef.jpg

Description

Bussmann Fusetron™ Time Delay Fuse, Current Limiting Renewable, Series: FRS-R, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 8 A, 600 VAC/300 VDC, 200 kA Interrupt, Class: RK5, 10 s at 500% Response, Ferrule Terminal, Holder Mount, Cylindrical Body Type, Dual Element, Fiberglass, 0.81 in Dia x 5 in L Body Size

Bussmann's UL Class RK5 Fusetron product offering provides energy efficient advanced protection with its dual-element, time-delay construction and is available with optional open fuse indication on select ratings. Available in both 250Vac and 600Vac, 200kA RMS Sym interrupting rating and sizes ranging from 0 to 600 amp. Fusetron's deliver 10 seconds (minimum) of time-delay at 500 of rated current (8 seconds for 1/10-30A sizes).

Features

  • Dual element feature provides the best time delay performance, allowing closer sizing and superior protection of motors and transformers
  • Closer sizing allows for smaller fuses and less costly switches
  • Class RK5 fuses with a 200 kA interrupt rating for use in a broad range of applications
  • Provides motor overload, ground fault and short circuit protection
  • Helps protect motors against burnout from overloads and single phasing when sized properly
  • Dual element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection
  • Offers a 10 sec time delay at 5 times the rated current
  • The time delay feature makes it possible to use fuse amperage ratings which are much smaller than those of non-time delay fuses
  • Considerable cost savings occur by permitting the use of smaller size switches, panels and fuses themselves
  • Provides current limitation to help protect downstream components from high fault currents
  • Gives motor running back-up protection to motors without extra cost

Specifications

GTIN: 00051712508261

UNSPSC: 39121606

Country of Origin: Mexico

Type
Current Limiting Renewable
Terminal Type
Ferrule
Interrupt Rating
200 kA
Body Type
Cylindrical
Element
Dual
Voltage Rating
600 VAC/300 VDC
Class
RK5
Mounting Type
Holder
Body Size
0.81 in Dia x 5 in L
Series
FRS-R
Indicating/Non-Indicating
Non-Indicating
Material
Fiberglass
Amperage Rating
8 A
Rejection/Non-Rejection
Rejection
Response Time
10 s at 500%
BABA Compliant
No
Sold as
EACH

Recently Viewed Products

Loading recently viewed products...

Reviews

Loading product reviews...
Loading product details...