GE CR306C004 Full Voltage Non-Reversing Non-Combination NEMA Magnetic Starter, 440 VAC at 50 Hz, 460 to 480 VAC at 60 Hz V Coil, 3 Poles, Open Enclosure

GE_CR306C004.jpg

Description

GE NEMA Magnetic Starter, Full Voltage Non-Reversing Non-Combination, Series: CR306, 600 VAC, 27 A, 50/60 Hz Frequency, 10 hp Motor, 440 VAC at 50 Hz, 460 to 480 VAC at 60 Hz Coil, 3 Pole, Manual Reset, 3 ph, Pressure Screw Terminal Connection, (2) 3 Leg Block Type Bimetal Overload Relay, Open Enclosure, -20 to 70 deg C Operating, 7 in H x 3.71 in W x 3.94 in D Dimensions

GE full voltage (600 V maximum) magnetic motor starter has an encapsulated coil and a 3-leg overload relay to protect against overloads in all phases. It is on standard specifications of major manufacturers. The line offers features and benefits most asked for by users.

Features

  • Tool less contactor disassembly (sizes 00 to 4) - allows quick access for inspection and maintenance
  • Just release two retainers and pull a clip to get at magnet, coil and contacts
  • Saddle clamp terminals (sizes 00 to 1) - accommodate ring, spade and stripped wire leads and carry permanent stamped in identification
  • Staggered arrangement makes wiring easier and helps prevent shorting between phases
  • Current carrying components - contact tips are weld-resistant silver cadmium oxide (fine silver on sizes 00 and 0 only)
  • Contacts are installed in a wedge configuration for positive make with minimum bounce
  • Class 20 overload protection
  • Visual trip indicator with manual reset - to avoid surprise restarts, reset occurs on arm upstroke so a tripped condition can't be overridden by holding the arm down
  • Manual weld check - provides a convenient test against welding of overload relay contacts, just depress the weld check operator to trip the relay, run a simple continuity test across the relay contacts, then depress the manual reset to return the starter to service
  • Dual bimetals - anticipate overloads, responding to rising current and temperature with faster tripping on severe overloads for better motor protection, trip points are factory-calibrated for accuracy
  • +/-10% trip adjustment - by turning a dial in the overload relay face allows tuning the protection to the motor on the spot
  • Largest selection of modifications and accessory kits - includes auxiliary contacts, coils, fifth-pole addition, vertical and horizontal mechanical interlocks, surge suppressors, control circuit fusing, NEMA type enclosures, push buttons, selector switches, indicating lights, control transformers, space heaters and more
  • List price includes a holding interlock, pressure terminals for the line and load connections, plus a 3-leg block type overload relay (manual reset)
  • All enclosures include external reset
  • Motor full load current should not exceed continuous ampere rating of the starter

Specifications

GTIN: 00783166356579

UNSPSC: 39121521

Type
Full Voltage Non-Reversing Non-Combination
Operating Temperature
-20 to 70 deg C
Number of Poles
3
Frequency Rating
50/60 Hz
Voltage Rating
600 VAC
Weight
59 lbs
Enclosure Type
Open
Motor Power
10 hp
Coil Voltage
440 VAC at 50 Hz, 460 to 480 VAC at 60 Hz
Series
CR306
Phase
3
Reset Type
Manual
Amperage Rating
27 A
Overload Relay
(2) 3 Leg Block Type Bimetal
BABA Compliant
No
Connection Type
Pressure Screw Terminal
Dimensions
7 in H x 3.71 in W x 3.94 in D
Sold as
EACH