Skip to main content Skip to main content

GE Record Plus FBN36TE030RV Type FBN Molded Case Circuit Breaker, 600Y/347 VAC, 30 A, 150 kA at 240 VAC/65 kA at 480 VAC Interrupt, 3 Poles, LI/Thermal Magnetic Trip

GE_FBV36TE020RV.jpg

Description

GE Record Plus Molded Case Circuit Breaker, Type FBN, 600Y/347 VAC, 30 A, 50/60 Hz, 150 kA at 240 VAC/65 kA at 480 VAC Interrupt, FB100 Frame, LI/Thermal Magnetic Trip, 3 Pole, 3 ph, Pivot/Toggle Handle Actuator, Load Lug/Panel, 10 to 4 AWG Wire, Panel Mount, -40 to 80 deg C, 4.11 in W x 3.28 in D x 6.45 in H, Plastic

Record Plus? represents the very latest in molded case circuit breaker design. Utilizing design features such as double break rotary contact structures and advanced ablative materials to enhance interruption, record Plus? is capable of interrupting ratings up to 200 kA (FC maximum is 150 kA). high kAIC ratings, selective coordination, reduced arc flash energy and current limitation embody the core design principles of record Plus?. FC 100 circuit breakers are supplied with factory installed non-user interchangeable thermal magnetic trip units and can be supplied with or without lugs. FC is available in 2 and 3-pole versions, both in a 3-pole footprint. record Plus? product numbers ending in R or R0 do not include lugs. an R1 suffix indicates that the breaker is supplied with line and load lugs, R2 indicates load lugs and R3 indicates line lugs. RV suffixed product numbers include load lugs and line connections specifically designed for GE type AD panels. all frames use common internal accessories (auxiliary switches, UV releases, shunt trips and bell alarms) UL listed for field installation. UL listed maximum short circuit ratings at 480 VAC are 150 kA for the 100 A frames and 200 kA for the 600 A frames. unless noted otherwise, all circuit breakers and accessories are listed in UL file No. E11592.

Features

  • Broad product line to meet virtually any application need
  • Reduced downtime
  • A tripped breaker is easily spotted and can be immediately reset after the fault has been corrected
  • Eliminates single phasing
  • A common trip bar disconnects all poles simultaneously on both overload and short circuits
  • Offers application flexibility through the use of a wide variety of accessory devices and special attachments
  • Repetitive operation no fuses to replace
  • Breakers can be repetitively tested
  • Fuses must be destroyed to confirm calibration accuracy
  • 150 kA at 240 VAC, 65 kA at 480 VAC interrupt rating

Specifications

GTIN: 00783164395150

UNSPSC: 39121601

Trip Type
LI/Thermal Magnetic
Interrupt Rating
150 kA at 240 VAC/65 kA at 480 VAC
Number of Poles
3
Frequency Rating
50/60 Hz
Voltage Rating
600Y/347 VAC
Actuator Type
Pivot/Toggle Handle
Weight
1.8 lbs
Width
3 in
Dimensions
4.11 in W x 3.28 in D x 6.45 in H
Mounting Type
Panel
Connection Type
Load Lug/Panel
Phase
3
Material
Plastic
Amperage Rating
30 A
Temperature Rating
-40 to 80 deg C
Frame
FB100
BABA Compliant
No
Wire Size
10 to 4 AWG
Type
Type FBN
Sold as
EACH

Recently Viewed Products

Loading recently viewed products...

Reviews

Loading product reviews...