GE Spec-Setter TDT3364 Fused Type TDT Double Throw Safety Switch, 600 VAC, 200 A, 30 hp, 50 hp, 60 hp, 150 hp, TPDT Contact, 3 Poles

GE_TC10323R.jpg

Description

GE Spec-Setter Safety Switch, Fused Type TDT Double Throw, 600 VAC, 200 A, 30 hp, 50 hp, 60 hp, 150 hp, 1/3 ph, 50/60 Hz Frequency, 3 Pole, 3 Wires, 100 kA Short Circuit, TPDT Contact Form, Handle Actuator, NEMA 1 Enclosure, 3-Point/Self-Leveling Mounting, Line/Load Lug Terminal, 60/75 deg C, 28.6 in W x 16.2 in D x 51.4 in H Dimensions, Steel, Hot Dipped Galvanized

GE Type TDT double throw safety switches are designed for applications with two sources of power where safety, high performance and continuity of service are essential. Double throw switches are available in 30 to 1200 A, 600 VAC, 250 VDC maximum in fusible and non-fusible construction and in NEMA Type 1 (indoor) and Type 3R (outdoor) and NEMA Type 4X (stainless steel) enclosures. GE double throw safety switches are UL Listed as service entrance equipment when installed in accordance with the National electrical Code. All GE double throw safety switches are UL and cUL Listed (UL 98 Enclosed switches and CSA C22.2 No. 4-04) and meet NEMA Enclosed safety switch standard KS1-2013.

Features

  • Bright red handle is easy to see and easy to grip
  • Highly visible ON/OFF/ON label takes the guesswork out of safety
  • Quick make/quick break operating mechanism
  • 3-position (ON/OFF/ON) handle is lockable
  • Lockable cover latch meets all safety inspection requirements
  • 60/75 deg C conductor ratings
  • Full cover interlocks
  • 15 hp at 240 VAC standard fuse, 15 hp at 240 VAC, 25 hp at 480 VAC standard fuse, 50 hp at 480 VAC time delay, 30 hp at 600 VAC standard fuse, 50 hp at 600 VAC time delay 1-phase, 25 hp at 240 VAC standard fuse, 25 hp at 240 VAC, 50 hp at 480 VAC standard fuse, 125 hp at 480 VAC time delay, 60 hp at 600 VAC standard fuse, 150 hp at 600 VAC time delay 3-phase, 40 hp at 250 VDC standard fuse, 40 hp at 250 VDC time delay horsepower rating

Specifications

GTIN: 00783164069471

UNSPSC: 39122205

Terminal Type
Line/Load Lug
Number of Wires
3
Number of Poles
3
Frequency Rating
50/60 Hz
Voltage Rating
600 VAC
Actuator Type
Handle
Weight
1.5 lbs
Enclosure Type
NEMA 1
Short Circuit Current Rating
100 kA
Mounting Type
3-Point/Self-Leveling
Phase
1/3
Material
Steel
Amperage Rating
200 A
Contact Form
TPDT
Finish
Hot Dipped Galvanized
Temperature Rating
60/75 deg C
Horsepower
30 hp, 50 hp, 60 hp, 150 hp
BABA Compliant
No
Dimensions
28.6 in W x 16.2 in D x 51.4 in H
Type
Fused Type TDT Double Throw
Sold as
EACH