Skip to main content Skip to main content

Siemens 87FUF6FC Class 87 Fusible Disconnect Standard Pump Control Panel, 220 to 480 VAC V Coil, NEMA 2/12/3R Enclosure

Siemens_87DUB6FA.jpg

Description

Siemens Pump Control Panel, Class 87 Fusible Disconnect Standard, 600 VAC, 60 A, 50/60 Hz Frequency, 8.6 W Wattage, 25 hp Motor, 220 to 480 VAC Coil, 19 to 29 ms On/10 to 24 ms Off Timing, Automatic/Manual/Remote Reset, 3 ph, Box Lug/Screw Connection, SZ 2 Size, Solid-State Overload Relay, 10 A at 600 VAC A600, 5 A at 600 VDC P600 Auxiliary, HAND/OFF/AUTO Selector Switch Control, NEMA 2/12/3R Enclosure, 10000000 Cycles Operating Cycles, -4 to 104 deg F Operating, 29 in H x 20 in W x 8 in D Dimensions

Features

  • -22 to 149 deg F during storage
  • 3NO contacts for main contacts
  • 0NC contacts at contactor for auxiliary contacts, 1NO contacts at contactor for auxiliary contacts, 7 total auxiliary contacts maximum
  • 220 to 480 VAC at 60 Hz/0 to 0 VAC 50 Hz
  • 8.6 W holding power at AC minimum
  • 218 VAC apparent pick up power of magnet coil, 25 VAC apparent holding power of magnet coil
  • 0.85 to 1.1 VDC operating range factor control supply voltage rated value of magnet coil
  • 50% drop-out voltage of magnet coil related to the input voltage
  • Overload protection, phase failure detection, phase unbalance, ground fault detection, test function, external reset overload relay function
  • 13 to 52 A adjustable pick up value current of the current dependent overload release
  • 3 sec trip time at phase loss maximum
  • Protective coating on printed circuit board
  • 5 A at 600 VAC/1 A at 250 VDC operating current of auxiliary contacts of overload relay
  • Vertical surface mounting and installation
  • 10 kA at 600 VAC (class H or K)/100 kA at 600 VAC (class R or J) design of the fuse link for short circuit protection of the main circuit required
  • 0 hp at 200/208 VAC/0 hp at 220/230 VAC/25 hp at 460/480 VAC/25 hp at 575/600 VAC electrical ratings

Specifications

GTIN: 00662643536720

UNSPSC: 39121521

Country of Origin: Mexico

Type
Class 87 Fusible Disconnect Standard
Operating Temperature
-4 to 104 deg F
Control Type
HAND/OFF/AUTO Selector Switch
Auxiliary Contact Rating
10 A at 600 VAC A600, 5 A at 600 VDC P600
Wattage
8.6 W
Timing
19 to 29 ms On/10 to 24 ms Off
Frequency Rating
50/60 Hz
Voltage Rating
600 VAC
Size
SZ 2
Weight
2 lbs
Width
4 in
Enclosure Type
NEMA 2/12/3R
Dimensions
29 in H x 20 in W x 8 in D
Motor Power
25 hp
Coil Voltage
220 to 480 VAC
Connection Type
Box Lug/Screw
Phase
3
Reset Type
Automatic/Manual/Remote
Amperage Rating
60 A
Operating Cycles
10000000 Cycles
Overload Relay
Solid-State
BABA Compliant
No
Sold as
1/PK

Recently Viewed Products

Loading recently viewed products...

Reviews

Loading product reviews...