Siemens 87LPU6MG Class 87 Full Voltage NEMA Starter Standard Pump Control Panel With MCP, 220 to 240 VAC V Coil, NEMA 3/3R Enclosure

Siemens_87DUB6MA.jpg

Description

Siemens Pump Control Panel, Full Voltage NEMA Starter Standard, Series: Class 87, 600 VAC, 270 A, 50/60 Hz Frequency, 7.4 W Wattage, 200 hp Motor, 220 to 240 VAC Coil, Setting: 55 to 250 A, 30 to 95 ms On/40 to 70 ms Off Timing, Automatic/Manual Reset, 3 ph, Box Lug/Screw Connection, SZ 5 Size, Solid-State Overload Relay, 10 A at 240 VAC (A300), 2.5 A at 250 VDC (Q300) Auxiliary, Start Pushbutton/Hand-Off-Auto Selector Switch Control, NEMA 3/3R Enclosure, Metal, 10000000 Cycles Operating Cycles, -4 to 104 deg F Operating, 72 in H x 20 in W x 11 in D Dimensions

The Siemens full voltage starter pump controllers are specifically designed for the agricultural, petrochemical and other industries requiring pump control. They are built to withstand the harsh elements of the outdoors and are well suited for the most demanding environments.

Features

  • Heavy duty NEMA starter sizes 1 to 6 including Siemens exclusive half size starters to provide reliable motor control and protection expected in the most demanding applications
  • The ESP200 solid state overload relay has a protective coating on the circuit board which gives it superior protection against high humidity, condensation and corrosive environments
  • Heavy duty disconnect switch with visible blades for safety and double break switch action to reduce arcing and increase lifetime
  • Line side shield on disconnect switch to help guard personnel from contact with live parts
  • Type 3/3R enclosure fabricated with galvannealed steel versus conventional cold rolled steel for superior corrosion resistance
  • Rugged 30 mm H-O-A switch and start push button, which are standard features, meet type 3, 4, 12 and 13 specifications and are oil and dust tight for durability
  • Pre-punched opening with cover plate for convenient field installation of a conduit hub should top entry be required
  • Full gasketed door to ensure a dust tight and water tight seal
  • Mounting flanges at top and bottom of enclosure for easy mounting on poles or flat surfaces using keyhole slots
  • Auxiliary control panel for field mounting additional controls or for use as a wire way for large power conductors
  • Heavy duty quarter-turns for fast entry and proper sealing of enclosure
  • Door is removable for ease of installation and maintenance
  • Factory and field modifications for custom applications
  • UL rated as service entrance equipment permitting equipment to be pole mounted and installed directly off of utility power lines

Specifications

GTIN: 00040892981230

UNSPSC: 39121521

Country of Origin: United States of America (the)

Type
Full Voltage NEMA Starter Standard
Operating Temperature
-4 to 104 deg F
Control Type
Start Pushbutton/Hand-Off-Auto Selector Switch
Auxiliary Contact Rating
10 A at 240 VAC (A300), 2.5 A at 250 VDC (Q300)
Wattage
7.4 W
Timing
30 to 95 ms On/40 to 70 ms Off
Frequency Rating
50/60 Hz
Voltage Rating
600 VAC
Size
SZ 5
Weight
105 lbs
Enclosure Type
NEMA 3/3R
Dimensions
72 in H x 20 in W x 11 in D
Setting
55 to 250 A
Motor Power
200 hp
Coil Voltage
220 to 240 VAC
Series
Class 87
Connection Type
Box Lug/Screw
Phase
3
Reset Type
Automatic/Manual
Material
Metal
Amperage Rating
270 A
Operating Cycles
10000000 Cycles
Overload Relay
Solid-State
BABA Compliant
No
Sold as
EACH