Skip to main content Skip to main content

GE TED134100WL Type TED Core E Mid Tier Molded Case Circuit Breaker With CopperAluminum Line and Load Lug, 480 VAC, 100 A, 18 kA Interrupt, 3 Poles, LINon-Interchangeable Thermal Magnetic Trip

GE_TED134100WL.jpg

Description

GE Molded Case Circuit Breaker, Type TED Core E Mid Tier, 480 VAC, 100 A, 50/60 Hz Frequency, 18 kA Interrupt, E150 Frame, LI/Non-Interchangeable Thermal Magnetic Trip, 3 Pole, 3 ph, Pivot/Toggle Handle Actuator, Line/Load Lug Connection, 3 to 1 AWG Wire, Bolted-On Mounting, 10 to 50 deg C, 6-5/16 in H x 4-1/8 in W x 3-3/8 in D Dimensions, Plastic

The E150 product line consists of thermal magnetic circuit breakers, magnetic circuit breakers and molded case switches rated up to 150 A and 600 VAC. catalog numbers include the complete breaker or switch. the WL catalog number suffix indicates that the devices come with copper aluminum line and load lugs.

Features

  • Molded case is molded from high mechanical and high dielectric strength engineered plastic
  • Trip indication is shown by handle position midway between ON and off to reset the trip mechanism, move the handle to extreme off then to ON position
  • Quick-make, quick-break, trip-free mechanism minimizes arcing during breaker operation, contacts cannot be ''teased'' into position
  • Trip-free mechanism is independent of manual handle control, the breaker trips under short circuit or overload, even though the operating handle is held in on position
  • VERIFIER "twist-to-trip" and ''push-to-trip'' mechanically simulates over current tripping through actuation of linkages not operated by the on-off handle
  • Common trip bar assures instant disconnect of all conductors when an overload or short circuit occurs on any one conductor in the circuit or an accessory trip device operates
  • Silver alloy contacts combine the conductive properties of silver with other elements for clean, positive electrical contacting, pitting and burning are minimized for longer contact life
  • Arc chutes of heat absorbing, insulating material and metal grid plates quickly ''extinguish'' arcs
  • UL listed lugs for copper or aluminum cable, at full frame rating, easy access and simple, straight in wiring
  • Proven reliability
  • Provide cost effective solutions
  • Multiple types to fit in your application
  • 10 kA at 125 VDC, 10 kA at 250 VDC, 10 kA at 500 VDC, 14 kA at 600 VAC, 18 kA at 120/240 VAC, 18 kA at 240 VAC, 18 kA at 277 VAC, 18 kA at 480 VAC interrupt rating

Specifications

Type
Type TED Thermal Magnetic
Number of Poles
3
Voltage Rating
480 VAC/250 VDC
Dimensions
6-5/16 in H x 4-1/8 in W x 3-3/8 in D
Mounting Type
Bolt-On
Phase
3
Amperage Rating
12 A
Temperature Rating
40 deg C
BABA Compliant
No
Connection Type
Line and Load Lug
Interrupt Rating
18/10 kA
Wire Size
3 to 3/0/1 to 3/0 AWG
Trip Type
Long Time and Instantaneous
Sold as

Recently Viewed Products

Loading recently viewed products...

Reviews

Loading product reviews...
Loading product details...