Bussmann Low-Peak LPN-RK-2SP Current Limiting Time Delay Fuse, 2 A, 250 VAC/125 VDC, 100/300 kA Interrupt, RK1 Class, Cartridge Body

IDW_IMAGE_a6e9e5e01a88413b2b122a146ce2af7c15446c4730b5130b086f5629212c6923.jpg

Description

Bussmann Low-Peak Time Delay Fuse, Current Limiting, Series: LPN-RK, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 2 A, 250 VAC/125 VDC, 100/300 kA Interrupt, Class: RK1, 8 s at 500% Response, Ferrule Terminal, Holder Mount, Cartridge Body Type, Dual Element, Melamine, 0.56 in Dia x 2 in L Body Size

Bussmann's UL Class RK1 fuse offering includes the industry's most recognized Low-Peak dual-element, current-limiting, time-delay fuses (LPN-RK and LPS-RK) which are also available with optional indication on select ratings (see product data sheet). Complementing the Low-Peak product offering is Bussmann's Limitron family of fast-acting fuses (KTN-R, KTS-R, KWN-R and KWS-R) fuses.

Features

  • Fast short circuit protection and dual element, time delay performance provide ultimate protection
  • Insulated end caps reduces exposure to live parts and extends air gap to distance between blades of adjacent mounted fuses or to housing
  • Current limitation protects downstream components against damaging thermal and magnetic effects of short circuit currents
  • Reduces existing fuse inventory by up to 33% when upgrading to Low-Peak fuses
  • Consistent 2:1 ampacity ratios for all Low-Peak fuses make selective co-ordination easy
  • Time delay that permits 130% FLA sizing for back up motor protection
  • Inventory consolidation of class RK1, RK5 and H fuses for reduced SKU investment and minimizing potential for misapplying fuse
  • Separate overload and short circuit elements provide time delay for close sizing of high inrush loads linked with RK1 current limitation and selective co-ordination ratio of 2:1 (within Low-Peak fuse family) prevents widespread blackouts
  • Protects against 1 ph motor damage
  • Proper sizing can provide "no damage" type 2 motor starter protection for NEMA and IEC motor controllers

Specifications

Type
Current Limiting
Terminal Type
Ferrule
Interrupt Rating
100/300 kA
Body Type
Cartridge
Element
Dual
Voltage Rating
250 VAC/125 VDC
Class
RK1
Mounting Type
Holder
Body Size
0.56 in Dia x 2 in L
Series
LPN-RK
Indicating/Non-Indicating
Non-Indicating
Material
Melamine
Amperage Rating
2 A
Rejection/Non-Rejection
Rejection
Response Time
8 s at 500%
BABA Compliant
No