Skip to main content Skip to main content

EATON BR1630L150 1-Phase Metallic Split Main Lug Load Center, 120240 VAC, 150 A, 30 Poles, 25 kA Interrupt

IDW_IMAGE_3c35f5c8bc801c29443bce1ef769cb077031abe1761bb2e8cf289fb231ecd92b.jpg

Description

EATON Main Lug Load Center, 1-Phase Metallic Split, 120/240 VAC, 150 A, 30 Pole, 25 kA Interrupt, 30 Circuits, BR/BWH Breaker, 3-Wire Wiring Configuration, 16 Spaces, 1 AWG to 300 kcmil Wire, Flush Mounting, NEMA 1 Enclosure, NEMA C2 Enclosure Box, 3.88 in L x 14.31 in W x 23 in D Dimensions

Loadcenters are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets.

Features

  • Twin neutral design located in wireway, away from circuit breakers, means easier wiring and balancing of the load
  • Extra 1-1/2 in knockout for bundling allows maximum wiring gutter space for ease of wiring in compliance with NEC requirements
  • 1-piece roll formed metal backpan with circuit breaker alignment notches ensures accurately aligned breaker and bus tabs
  • Standard 14-3/8 in W enclosures fit snugly between wall studs
  • Tangential main knockout eliminates the need for conduit offsets which permits faster, easier installation
  • BR loadcenters feature Robertson® slotted square combo screw heads, which means only one screwdriver is need for installation
  • For use with type BR 1 in breakers
  • Indoor enclosure
  • Copper aluminum wire at 60 to 75 deg C for main lugs
  • Standard tin plated aluminum bus for excellent conductivity and corrosion-resistance
  • No feed through lugs
  • Combination mounting

Specifications

GTIN: 00786676447157

UNSPSC: 39121101

Country of Origin: United States of America (the)

Interrupt Rating
25 kA
Wiring Configuration
3-Wire
Number of Poles
30
Enclosure Box Size
NEMA C2
Voltage Rating
120/240 VAC
Number of Spaces
16
Enclosure Type
NEMA 1
Dimensions
3.88 in L x 14.31 in W x 23 in D
Mounting Type
Flush
Number of Circuits
30
Amperage Rating
150 A
BABA Compliant
No
Breaker Type
BR/BWH
Wire Size
1 AWG to 300 kcmil
Type
1-Phase Metallic Split
Sold as
EACH

Recently Viewed Products

Loading recently viewed products...

Reviews

Loading product reviews...
Loading product details...