Description
EATON Main Lug Loadcenter, 3-Phase Standard, 208Y/120/240 VAC, 125 A, 12 Pole, 10 kA Interrupt, 6 Circuits, CH Breaker, 4-Wire Wiring Configuration, 125 A Bus, 6 Spaces, 14 to 1/1 AWG Wire, Surface/Plug-On Mount, NEMA 3R, NEMA 7R Enclosure Box, Metal Housing, 13 in L x 11 in W x 3.56 in H
EATON CH 3/4 in loadcenters enclose CH breakers for power distribution and circuit protection in residential and light commercial applications. Also called a breaker box, electrical box or even a fuse box, the main function is to take electricity supplied by the utility and distribute it throughout the home to feed lights and receptacles. They are used on services providing no more than 240 VAC and are available with bus rated 40 to 600 A. Covers are available as surface, flush or combination.
Features
- One-piece silver flash plated copper bus provides superior conductivity throughout the entire product line
- Steel backpan provides positive, reliable mounting
- CH 150 to 225 a main breakers are rated 25 kA providing contractors with the highest interrupting rating main breaker in the industry
- Unique sandalwood finish provides an esthetically appealing, scratch resistant powder coating
- Type CH breakers include an industry exclusive "trip to Off" feature that allows a homeowner to easily identify a tripped circuit breaker
- Copper bus
- Loadcenter has overhead feeders and top bottom feed location for convenience
- It accommodates copper/aluminum wire at 60 to 75 deg C
- Insulated/bondable single neutral
- Straight-in wiring saves labor and material
- Bonding Z-strap provides easy field conversion for service entrance applications
- Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not more than six service disconnecting means are provided and when not used as a lighting and appliance panelboard
- Use GBK10 ground bar
- Ground bars mount to the left side wall of the enclosure
- Rainproof loadcenters are furnished with hub closure plates, for rainproof hubs
Specifications
GTIN: 00782114229255
UNSPSC: 39121101
Country of Origin: United States of America (the)
| Type | 3-Phase Standard |
|---|---|
| Interrupt Rating | 10 kA |
| Wiring Configuration | 4-Wire |
| Number of Poles | 12 |
| Voltage Rating | 208Y/120/240 VAC |
| Breaker Type | CH |
| Enclosure Type | NEMA 3R |
| Mounting Type | Surface/Plug-On |
| Bus Rating | 125 A |
| Amperage Rating | 125 A |
| BABA Compliant | No |
| Housing Material | Metal |
| Number of Spaces | 6 |
| Enclosure Box Size | NEMA 7R |
| Wire Size | 14 to 1/1 AWG |
| Dimensions | 13 in L x 11 in W x 3.56 in H |
| Number of Circuits | 6 |
| Sold as | EACH |