EATON Arrow Hart SGF15GY-L SGF Duplex Grounding Self-Test GFCI Receptacle, 125 VAC, 15 A, 2 Poles, 3 Wires, Gray

IDW_IMAGE_3bc2cb37e90a6d29e5e8f58e3db5295439b6831a1435774c15807e4963a56c7f.jpg

Description

EATON Arrow Hart GFCI Receptacle, Duplex Grounding Self-Test, Series: SGF, 125 VAC, 15 A, 60 Hz Frequency, 2 Pole, 3 Wires, NEMA 5-15R NEMA Rating, Specification Grade, -31 to 150.8 deg F, Screw Terminal, Polypropylene/PVC/Thermoplastic, Gray, 4.2 in H x 1.68 in W x 1.27 in D Dimensions

Eaton Arrow Hart line of GFCI receptacles ensure electrical shock protection with periodical automatic testing. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow notifying the user there is no power and the device must be replaced. GFCI receptacles are available in a number of grades including hospital, tamper resistant, non-tamper resistant and weather resistant, as well as a variety of colors including white, ivory, almond, light almond, black, brown, gray and red.

Features

  • Performs periodic self-tests to ensure integrity of GFCI protection
  • Visual trip indicator light gives quick notification of a tripped or "end of life" condition
  • Meets and exceeds 10 kA short circuit testing and UL 943 safety standards
  • Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used
  • Ground termination with back wire clamp provides secure wiring and reduces installation time
  • Tamper resistant shutters help prevent foreign objects from being inserted
  • Line side terminals are backed out and staked for fast installation
  • Horizontal test/reset button alignment provides larger unobstructed area
  • Test and reset buttons are color matched to provide superior aesthetics
  • Tapered back wire openings handle multiple wire sizes and types for applications up to 10 AWG solid or stranded wire
  • When downstream receptacles are wired from load side, a 20 A feed-through rating offers full protection
  • Line load miswiring protection, GFCIs will not provide power downstream when wired incorrectly
  • Tri-combo head terminal and mounting screws
  • UL Listed, fully compliant with all latest UL 943 class A GFCI requirements
  • Longer, wider "bridged" strap provides 40% more contact area with wallboard, virtually eliminating floating installations