Skip to main content Skip to main content

Eaton Wiring Devices SGF20W SGF Duplex GFCI Receptacle, 125 VAC, 20 A, 2 Poles, 3 Wires, White

Cooper_Wiring_SGF15W.jpg

Description

Eaton Wiring Devices GFCI Receptacle, Duplex, Series: SGF, 125 VAC, 20 A, 60 Hz Frequency, 2 Pole, 3 Wires, NEMA 5-20R NEMA Rating, IP65 Enclosure, -35 to 66 deg C, Back/Side Wire Terminal, Thermoplastic, White, 4.2 in L x 1.68 in W x 1.27 in D Dimensions

Eaton's Arrow Hart line of self-test GFCI receptacles ensure electrical shock protection with periodical automatic testing. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow notifying the user there is no power and the device must be replaced. Self-Test GFCI receptacles are available in a number of grades including hospital, tamper resistant, non-tamper resistant and weather resistant, as well as a variety of colors including white, ivory, almond, light almond, black, brown, gray and red.

Features

  • If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow notifying the user there is no power and the device must be replaced
  • Performs periodic self-tests to ensure integrity of GFCI protection
  • Visual trip indicator light gives quick notification of a tripped or end of life condition
  • Meets and exceeds 10 kA short circuit testing and Underwriters Laboratories (UL) UL943 safety standards
  • Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used
  • Tamper resistant shutters help prevent foreign objects from being inserted
  • Line side terminals are backed out and staked for fast installation
  • Horizontal test/reset button alignment provides larger unobstructed area
  • Test and reset buttons are color matched to provide superior aesthetics
  • Tapered back wire openings handle multiple wire sizes and types for applications up to 10 AWG solid or stranded wire
  • When downstream receptacles are wired from load side, a 20A feed through rating offers full protection
  • Line-load miswiring protection: GFCIs will not provide power downstream when wired incorrectly
  • Tri-combo head terminal and mounting screws
  • Longer, wider bridged strap provides 40% more contact area with wallboard, virtually eliminating floating installations
  • Thermoplastic, polypropylene top housing, thermoplastic, PVC bottom housing, 0.047 in thick steel, zinc plated strap, 0.03 in thick brass line contacts material
  • #8-32 steel, brass plated, neutral screw nickel plated, ground screw green terminal and ground screws, 0.07 in thick steel terminal clamps
  • Withstands 2000 V per UL498 dielectric voltage
  • V2 rated UL94 flammability
  • Current interrupting at full-rated current, 0.025 sec class A trip time, Short circuit testing meets and exceeds 10 kA, maximum interrupting capacity of 20 A
  • #14 to 10 AWG terminal accommodation, Back Wire and Side Wire

Specifications

UNSPSC: 39121406

Number of Wires
3
Number of Poles
2
Color
White
Frequency Rating
60 Hz
Voltage Rating
125 VAC
NEMA Rating
NEMA 5-20R
Amperage Rating
20 A
BABA Compliant
No
Temperature Rating
-35 to 66 deg C
Material
Thermoplastic
Dimensions
4.2 in L x 1.68 in W x 1.27 in D
Enclosure
IP65
Terminal Type
Back/Side Wire
Type
Duplex
Series
SGF
Sold as
1/PK