Appleton® ST-50L ST Series Non-Insulated Straight Liquid Tight Conduit Connector With External Grounding Lug, 1/2 in Trade, Steel, Electroplated Zinc

Image asset. Press spacebar to set to main image.

Description

Appleton® Liquid Tight Conduit Connector, Non-Insulated Straight, Series: ST Series, 1/2 in Trade, For Use With: Liquid Tight Flexible Metal Conduit Fitting, Steel, Electroplated Zinc, 1.44 in L x 1.25 in W Dimensions

Appleton® offers a full range of Class I Division 2 Liquidtight connectors ideally suited for OEM equipment, as well as harsh and corrosive environments. With only three main parts the body, long-throat crimpable ferrule and compression nut Appleton® ST connectors are, at minimum, 25% quicker to install than the competitor's. In addition, the breadth of Appleton® ST Liquidtight product line offers a vast range of trade sizes, configurations, and male and female versions in both aluminum and steel. For all these reasons, Appleton® is the top choice whenever a secure, safe connection is paramount.

Features

  • Malleable iron and/or steel construction, steel or aluminum ferrule, polypropylene sealing ring
  • Unique long ferrule with pronounced threads provides over four times UL pull out requirements
  • Ferrule provides maximum surface contact for better sealing and a continuous, permanent, positive metal to metal ground
  • Adequately sized bonded lugs provide excellent grounding continuity and allow for visible ground path inspection
  • Liquidtight, raintight and oiltight
  • Suitable for outdoor use
  • Full, machined tapered threads (npt)
  • Straight, 45 and 90 deg styles available in trade sizes 3/8 through 4 in
  • Machine tool building, motor and transformer terminations, robotics assembly, air conditioning equipment installation and other applications that require flexibility and protection against entry of liquids, vapors or solids
  • ST-L Series has plain throat, STB-L Series has insulated throat to protect against wire damage
  • Suitable for use in hazardous locations Class I, Division 2, Class II, Div. 1 and 2, Class III, Div. 1 and 2, NEC 501-4(b), 502-4(a)(2), 503-3(a)
  • 0.63 in L thread

Specifications

GTIN: 00781381403078

UNSPSC: 39121420

Country of Origin: Mexico

Suitable For Use With
Liquid Tight Flexible Metal Conduit Fitting
Material
Steel
BABA Compliant
No
Finish
Electroplated Zinc
Series
ST Series
Dimensions
1.44 in L x 1.25 in W
Trade Size
1/2 in
Type
Non-Insulated Straight
Sold as
EACH