Skip to main content Skip to main content

GE TED134YT150 Type TED Core E Mid Tier Molded Case Circuit Breaker, 480 VAC, 150 A, 18 kA Interrupt, 3 Poles, Molded Case Switch/Non-Automatic/Thermal Magnetic Trip

GE_THED136020WL.jpg

Description

GE Molded Case Circuit Breaker, Type TED Core E Mid Tier, 480 VAC, 150 A, 50/60 Hz Frequency, 18 kA Interrupt, E150 Frame, Molded Case Switch/Non-Automatic/Thermal Magnetic Trip, 3 Pole, 3 ph, Toggle Handle Actuator, Load Lug Connection, Bolted-On Mounting, 10 to 50 deg C, 4-1/8 in W x 3-3/8 in D x 6-5/16 in H Dimensions, Plastic

The E150 product line consists of thermal magnetic circuit breakers, magnetic circuit breakers and molded case switches rated up to 150 A and 600 VAC. Catalog numbers include the complete breaker or switch. The WL catalog number suffix indicates that the devices come with copper/aluminum line and load lugs. All TEB, TED, THED breakers suitable for reverse feed. 60/75 deg C rating through 100 A, 75 deg C rating above 100 A.

Features

  • Molded case is molded from high mechanical and high dielectric strength engineered plastic
  • Trip indication is shown by handle position midway between On and Off to reset the trip mechanism, move the handle to extreme off then to On position
  • Quick make, quick break, trip free mechanism minimizes arcing during breaker operation, contacts cannot be ''teased'' into position
  • Trip-free mechanism is independent of manual handle control, the breaker trips under short circuit or overload, even though the operating handle is held in on position
  • VERIFIER® "Twist-to-Trip" and ''Push-to-Trip'' mechanically simulates over current tripping through actuation of linkages not operated by the On/Off handle
  • Common trip bar assures instant disconnect of all conductors when an overload or short circuit occurs on any one conductor in the circuit or an accessory trip device operates
  • Silver alloy contacts combine the conductive properties of silver with other elements for clean, positive electrical contacting, pitting and burning are minimized for longer contact life
  • Arc chutes of heat absorbing, insulating material and metal grid plates quickly ''extinguish'' arcs
  • UL listed lugs for copper or aluminum cable, at full frame rating, easy access and simple, straight-in wiring
  • Suitable for reverse feed applications
  • 10 kA at 125 VDC, 10 kA at 250 VDC, 10 kA at 500 VDC, 14 kA at 600 VAC, 18 kA at 120 VAC, 18 kA at 120/240 VAC, 18 kA at 240 VAC, 18 kA at 277 VAC, 18 kA at 480 VAC interrupt rating

Specifications

GTIN: 00783164190939

UNSPSC: 39121601

Type
Type TED Core E Mid Tier
Trip Type
Molded Case Switch/Non-Automatic/Thermal Magnetic
Interrupt Rating
18 kA
Number of Poles
3
Frequency Rating
50/60 Hz
Voltage Rating
480 VAC
Actuator Type
Toggle Handle
Weight
92.6 lbs
Dimensions
4-1/8 in W x 3-3/8 in D x 6-5/16 in H
Mounting Type
Bolted-On
Connection Type
Load Lug
Phase
3
Material
Plastic
Amperage Rating
150 A
Temperature Rating
10 to 50 deg C
Frame
E150
BABA Compliant
No
Sold as
EACH