Siemens Sentron 3NE1218-4 Photovoltaic Fuse Link With Front Indicator, 63 A, 1000 V, 30 kA Interrupt, Class: gPV

Siemens_3NE1218_4.jpg

Description

Siemens Sentron Fuse Link, Photovoltaic, Indicating, 63 A, 1000 V, 30 kA Interrupt, Class: gPV, 30 kA Short Circuit Current, Blade Terminal, Surface Mount, NH1 Body Size

Special demands are made on fuses for application in photovoltaic systems. These fuses have a high DC rated voltage and a tripping characteristic specially designed to protect PV modules and their connecting cables (the newly defined operational Class gPV). It is also crucial that the PV fuses do not age in spite of strongly alternating load currents, in order to ensure high plant availability throughout the service life of the PV system. The fuses must also be able to withstand high temperature fluctuations without damage. These requirements were only incorporated into an international standard in recent years and have now been published as IEC 60269-6. All Siemens photovoltaic fuse systems comply with this new standard. Furthermore, they also already comply with the recently agreed corrections to the characteristic curves, which will be incorporated in the next standard update. The IEC cylindrical fuses used as phase fuses also correspond to the characteristic curves specified in UL standard UL 2579. The non-fusing current Inf and fusing current If test currents are crucial to the shape of the characteristic curves. These test currents of gPV phase fuses to 32 A apply for a conventional test duration of 1 hr at Inf, the fuse must not trip within an hour, at If, it must trip within an hour. The PV cylindrical fuses of size 10 x 38 mm offer an especially space saving solution for the protection of the strings. The fuse holders of size 10 x 38 mm can be supplied in 1-pole and 2-pole versions with and without signal detectors. In the case of devices with signal detector, a small electronic device with LED is located behind an inspection window in the plug-in module. If the inserted fuse link is tripped, this is indicated by the LED flashing. The devices have a sliding catch that enables removal of individual devices from the assembly. The infeed can be from the top or the bottom. Because the cylindrical fuse holders are fitted with the same anti-slip terminals at the top and the bottom, the devices can also be bus-mounted at the top or the bottom. The PV fuses in LV HRC design are usually used as cumulative fuses upstream of the inverter. In addition, they can also be used for protecting groups (PV subarrays). For the PV cumulative fuses of size 1, standard LV HRC fuse bases are available. For PV cumulative fuses of size 1L, 1XL, 2L, 2XL and 3L, we have developed a special 3NH7...-4 fuse base with a swiveling mechanism which combines maximum touch protection with maximum user friendliness. This makes it possible to change fuses safely and without the need for any tools, such as a fuse handle. This provides safe and fast access even in an emergency. Our cylindrical fuse holders and fuse bases with swiveling mechanism comply with the IEC 60269-2 standard and are considered fuse disconnectors as defined in the IEC 60947 switchgear and control gear standard. Under no circumstances are they suitable for switching loads. To ensure that PV fuses are correctly selected and dimensioned, the specific operating conditions and the PV module data must be taken into account when calculating voltage and current ratings.

Features

  • Protection of the modules and their connecting cables in the event of reverse currents
  • Safe tripping in case of fault currents reduces the risk of fire due to DC electric arcs
  • Safe separation when the fuse holder/fuse base is open

Specifications

GTIN: 00804766161551

UNSPSC: 39121626

Country of Origin: Germany

Terminal Type
Blade
Short Circuit Current Rating
30 kA
Mounting Type
Surface
Indicating/Non-Indicating
Indicating
Amperage Rating
63 A
BABA Compliant
No
Body Size
NH1
Type
Photovoltaic
Voltage Rating
1000 V
Class
gPV
Interrupt Rating
30 kA
Sold as
EACH