Siemens Pump Control Panel, Reduced Voltage, Series: Class 88, 230 VAC, 115 A, 50/60 Hz Frequency, 14 W Wattage, 40 hp Motor, 110 to 120 VAC Coil, Setting: 500 to 1250 A, 26 to 41 ms On/14 to 19 ms Off Timing, Automatic/Manual/Remote Reset, 3 ph, Box Lug/Screw Connection, SZ 3.5 Size, Solid-State Overload Relay, 10 A at 600 VAC (A600), 5 A at 600 VDC (P600) Auxiliary, Start Pushbutton/Hand-Off-Auto Selector Switch Control, NEMA 3/3R Enclosure, 5000000 Cycles Operating Cycles, -4 to 104 deg F Operating, 55 in H x 28 in W x 11 in D Dimensions
The Siemens reduced voltage starter pump controllers are designed for the same applications and environments the Class 87 full voltage starter pump controllers serve. However, these controllers provide added protection for your equipment. When energized, full voltage starters can cause excessive pressure surges in centrifugal pumping systems. These pressure surges induce stress in the piping which causes "water hammering." Even worse than the noise produced from the water hammering is the equipment damage that pressure surges may cause. This damage can include, among other things, ruptured pipes, loosened or broken pipe supports and damaged valves. The Siemens NEMA reduced voltage pump controllers are designed to reduce damage to your equipment. This is accomplished by stepping up the motor speed and thus reducing starting torque. A second reason for using reduced voltage controllers is to comply with electrical current restrictions of utility companies. Siemens manufactures the three commonly used NEMA reduced voltage pump controllers. This consists of the auto transformer, wye-delta and part-winding starters. Each type of starter is designed for specific application requirements. In addition to reducing starting torque, they also reduce inrush current and provide smoother acceleration of the pump.
Features
- Heavy duty NEMA starter sizes 1 to 6 including Siemens exclusive half size starters to provide reliable motor control and protection expected in the most demanding applications
- The ESP200 solid state overload relay has a protective coating on the circuit board which gives it superior protection against high humidity, condensation and corrosive environments
- Adjustable starting time
- CPT supplied as standard
- Type 3/3R enclosure which is fully gasketed to ensure a dust tight and water tight seal
- Rugged 30 mm H-O-A switch and start push button, which are standard features, meet type 3, 4, 12 and 13 specifications and are oil and dust tight for durability
- Door is removable for ease of installation and maintenance
- Factory and field modifications for custom applications
- UL rated as service entrance equipment permitting equipment to be pole mounted and installed directly off of utility power lines
Specifications
GTIN: 00040892948349
UNSPSC: 39121521
Country of Origin: United States of America (the)
| Operating Temperature | -4 to 104 deg F |
|---|---|
| Control Type | Start Pushbutton/Hand-Off-Auto Selector Switch |
| Wattage | 14 W |
| Timing | 26 to 41 ms On/14 to 19 ms Off |
| Frequency Rating | 50/60 Hz |
| Voltage Rating | 230 VAC |
| Enclosure Type | NEMA 3/3R |
| Setting | 500 to 1250 A |
| Motor Power | 40 hp |
| Coil Voltage | 110 to 120 VAC |
| Series | Class 88 |
| Connection Type | Box Lug/Screw |
| Phase | 3 |
| Reset Type | Automatic/Manual/Remote |
| Amperage Rating | 115 A |
| Operating Cycles | 5000000 Cycles |
| Overload Relay | Solid-State |
| BABA Compliant | No |
| Dimensions | 55 in H x 28 in W x 11 in D |
| Size | SZ 3.5 |
| Auxiliary Contact Rating | 10 A at 600 VAC (A600), 5 A at 600 VDC (P600) |
| Type | Reduced Voltage |
| Sold as | EACH |