Skip to main content Skip to main content

Siemens 88LPUP4FH Class 88 Reduced Voltage Pump Control Panel With Fusible Disconnect, 440 to 480 VAC V Coil, NEMA 3/3R/12 Enclosure

Siemens_88IUHT2MF.jpg

Description

Siemens Pump Control Panel, Reduced Voltage, Series: Class 88, 460 VAC, 270 A, 50/60 Hz Frequency, 7.4 W Wattage, 350 hp Motor, 440 to 480 VAC Coil, Setting: 55 to 250 A, 30 to 95 ms On/40 to 80 ms Off Timing, Automatic/Manual Reset, 3 ph, Box Lug/Screw Connection, SZ 5 Size, Solid-State Overload Relay, 10 A at 240 VAC (A300), 2.5 A at 250 VDC (Q300) Auxiliary, Start Pushbutton/Hand-Off-Auto Selector Switch Control, NEMA 3/3R/12 Enclosure, 10000000 Cycles Operating Cycles, -4 to 104 deg F Operating, 90 in H x 30 in W x 20 in D Dimensions

The Siemens reduced voltage starter pump controllers are designed for the same applications and environments the Class 87 full voltage starter pump controllers serve. However, these controllers provide added protection for your equipment. When energized, full voltage starters can cause excessive pressure surges in centrifugal pumping systems. These pressure surges induce stress in the piping which causes "water hammering." Even worse than the noise produced from the water hammering is the equipment damage that pressure surges may cause. This damage can include, among other things, ruptured pipes, loosened or broken pipe supports and damaged valves. The Siemens NEMA reduced voltage pump controllers are designed to reduce damage to your equipment. This is accomplished by stepping up the motor speed and thus reducing starting torque. A second reason for using reduced voltage controllers is to comply with electrical current restrictions of utility companies. Siemens manufactures the three commonly used NEMA reduced voltage pump controllers. This consists of the auto transformer, wye-delta and part-winding starters. Each type of starter is designed for specific application requirements. In addition to reducing starting torque, they also reduce inrush current and provide smoother acceleration of the pump.

Features

  • Heavy duty NEMA starter sizes 1 to 6 including Siemens exclusive half size starters to provide reliable motor control and protection expected in the most demanding applications
  • The ESP200 solid state overload relay has a protective coating on the circuit board which gives it superior protection against high humidity, condensation and corrosive environments
  • Adjustable starting time
  • CPT supplied as standard
  • Type 3/3R enclosure which is fully gasketed to ensure a dust tight and water tight seal
  • Rugged 30 mm H-O-A switch and start push button, which are standard features, meet type 3, 4, 12 and 13 specifications and are oil and dust tight for durability
  • Door is removable for ease of installation and maintenance
  • Factory and field modifications for custom applications
  • UL rated as service entrance equipment permitting equipment to be pole mounted and installed directly off of utility power lines

Specifications

GTIN: 00040892568899

UNSPSC: 39121521

Country of Origin: United States of America (the)

Operating Temperature
-4 to 104 deg F
Frequency Rating
50/60 Hz
Enclosure Type
NEMA 3/3R/12
Phase
3
Operating Cycles
10000000 Cycles
Overload Relay
Solid-State
BABA Compliant
No
Amperage Rating
270 A
Reset Type
Automatic/Manual
Connection Type
Box Lug/Screw
Series
Class 88
Motor Power
350 hp
Setting
55 to 250 A
Voltage Rating
460 VAC
Control Type
Start Pushbutton/Hand-Off-Auto Selector Switch
Auxiliary Contact Rating
10 A at 240 VAC (A300), 2.5 A at 250 VDC (Q300)
Wattage
7.4 W
Timing
30 to 95 ms On/40 to 80 ms Off
Size
SZ 5
Weight
0
Width
21.3 in
Dimensions
90 in H x 30 in W x 20 in D
Coil Voltage
440 to 480 VAC
Type
Reduced Voltage
Sold as
EACH