Skip to main content Skip to main content

Siemens TPS3E12150X0 External Surge Protective Device, 480Y/277 VAC, 200 kA SCCR, 3 Phase

Image asset. Press spacebar to set to main image.

Description

Siemens Surge Protective Device, External, Series: TPS3, 480Y/277 VAC Electrical Rating, 4 Wires, 200 kA Short Circuit, 150 kA Peak Surge Current, 20 kA Nominal Discharge, Modes of Protection: L-N/L-G/N-G/L-L, LED/Audible Alarm Indicator, 3 ph, NEMA 1/12/3R/04 Enclosure, Wall Mounting, 12 in H x 12 in W x 7 in D Dimensions

TPS3 12 and TPS3 L12 are UL 1449 3rd edition listed replaceable module, multimode Type 1 surge protective device with a per phase surge current capacity that can be increased to 500 kA (TPS3 L12 up to 450 kA). For mission critical or high profile applications, the TPS3 L12 is our "True" or "Discrete" 10-mode style SPD providing the "Just in Case" assurance of directly connected L-L MOVs. Both TPS3 12 and TPS3 L12 are UL 1283 Listed incorporating EMI/RFI or Sine Wave tracking filtering designed to condition low energy L-N coupled noise. When installed at the electrical service entrance, it can be used for UL 96A compliance (@ 20 kA In). Standard monitoring includes protection status indication LEDs, audible alarm, and dry contacts. Complete protection is intact when the status indicators are illuminated. When protection is lost, the status indicator will extinguish, the red service light will illuminate, and the dry contacts will change state. An optional surge counter is available. A new diagnostic feature integrated within the TPS3 12 and TPS3 L12 is Ground Integrity Monitoring or (GIM) diagnostic indication circuit. Ground Integrity Monitoring or (GIM) diagnostics monitors the health of the electrical systems neutral to ground bond. If voltage is seen across neutral and ground, the phase indicators will remain illuminated, while the red service light begins to flash alerting the end user that the electrical system grounding needs to be checked and serviced. This feature can be remotely monitored via the dry contact outputs. Siemens TPS3s are one of the first in the industry to offer this power quality safety and performance indication.

Features

  • Every MOV is monitored, including N-G
  • Ground integrity monitoring diagnostics
  • Audible alarm with silence switch and test button
  • Dry contacts
  • Surge counter
  • Wall/Chase nipple mounting
  • Type 1

Specifications

UNSPSC: 39121610

Country of Origin: United States of America (the)

Number of Wires
4
Modes of Protection
L-N/L-G/N-G/L-L
Nominal Discharge Current
20 kA
Enclosure Type
NEMA 1/12/3R/04
Short Circuit Current Rating
200 kA
Dimensions
12 in H x 12 in W x 7 in D
Peak Surge Current
150 kA
Mounting Type
Wall
Series
TPS3
Phase
3
Indicator Type
LED/Audible Alarm
Electrical Ratings
480Y/277 VAC
BABA Compliant
No
Type
External
Sold as