Siemens US2:88HUGP4FF Class 88 2-Step Part Winding Reduced Voltage Pump Panel, 110/120 VAC V Coil, NEMA 3/3R Enclosure

Image asset. Press spacebar to set to main image.

Description

Siemens Reduced Voltage Pump Panel, 2-Step Part Winding, Series: Class 88, 460 VAC, 90 A, 50/60 Hz Frequency, 14 W Wattage, 75 hp Motor, 110/120 VAC Coil, Setting: 25 to 100 A, 26 to 41 ms Switch-On Delay Time/14 to 19 ms Switch-Off Delay Time Timing, Automatic/Manual Reset, 3 ph, Box Lug/Screw Terminal Connection, SZ 3 Size, Solid-State Overload Relay, 10 A at 600 VAC/5 A at 600 VDC Auxiliary, Start Pushbutton/Hand-Off-Auto Selector Switch Control, NEMA 3/3R Enclosure, Metal, 5000000 Cycles Operating Cycles, 104 deg F Operating, 28 in W x 11 in D x 55 in H Dimensions

The Siemens Class 88 reduced voltage starter pump controllers consist of the same type of Class 37 starters and their benefits with added features. The added features make the Class 88 ideal for pump control applications.

Features

  • Type 3/3R enclosure which is fully gasketed to ensure a dust tight and water tight seal
  • Rugged 30 mm HOA switch and start pushbutton as standard
  • The ESP200 solid state overload relay has a protective coating on the circuit board which gives it superior protection against high humidity, condensation and corrosive environments
  • Latest technology in arc quenching to extend contactor life
  • 200 A fusible disconnect

Specifications

GTIN: 00887621770938

UNSPSC: 39121521

Country of Origin: United States of America (the)

Operating Temperature
104 deg F
Control Type
Start Pushbutton/Hand-Off-Auto Selector Switch
Wattage
14 W
Frequency Rating
50/60 Hz
Voltage Rating
460 VAC
Weight
107 lbs
Enclosure Type
NEMA 3/3R
Dimensions
28 in W x 11 in D x 55 in H
Setting
25 to 100 A
Motor Power
75 hp
Coil Voltage
110/120 VAC
Connection Type
Box Lug/Screw Terminal
Phase
3
Reset Type
Automatic/Manual
Material
Metal
Operating Cycles
5000000 Cycles
Overload Relay
Solid-State
BABA Compliant
No
Size
SZ 3
Auxiliary Contact Rating
10 A at 600 VAC/5 A at 600 VDC
Type
2-Step Part Winding
Series
Class 88
Amperage Rating
90 A
Timing
26 to 41 ms Switch-On Delay Time/14 to 19 ms Switch-Off Delay Time
Sold as
EACH