Skip to main content Skip to main content

Siemens US2:88HUGT4MJ Class 88 Reduced Voltage Pump Control Panel With MCP, 24 VAC V Coil, NEMA 3/3R/12 Enclosure

Siemens_88IUHT2MF.jpg

Description

Siemens Pump Control Panel, Reduced Voltage, Series: Class 88, 460 VAC, 90 A, 50/60 Hz Frequency, 14 W Wattage, 50 hp Motor, 24 VAC Coil, Setting: 315 to 1000 A, 26 to 41 ms On/14 to 19 ms Off Timing, Automatic/Manual/Remote Reset, 3 ph, Box Lug/Screw Connection, SZ 3 Size, Solid-State Overload Relay, 10 A at 600 VAC (A600), 5 A at 600 VDC (P600) Auxiliary, Start Pushbutton/Hand-Off-Auto Selector Switch Control, NEMA 3/3R/12 Enclosure, 5000000 Cycles Operating Cycles, -4 to 104 deg F Operating, 55 in H x 28 in W x 11 in D Dimensions

The Siemens reduced voltage starter pump controllers are designed for the same applications and environments the Class 87 full voltage starter pump controllers serve. However, these controllers provide added protection for your equipment. When energized, full voltage starters can cause excessive pressure surges in centrifugal pumping systems. These pressure surges induce stress in the piping which causes "water hammering." Even worse than the noise produced from the water hammering is the equipment damage that pressure surges may cause. This damage can include, among other things, ruptured pipes, loosened or broken pipe supports and damaged valves. The Siemens NEMA reduced voltage pump controllers are designed to reduce damage to your equipment. This is accomplished by stepping up the motor speed and thus reducing starting torque. A second reason for using reduced voltage controllers is to comply with electrical current restrictions of utility companies. Siemens manufactures the three commonly used NEMA reduced voltage pump controllers. This consists of the auto transformer, wye-delta and part-winding starters. Each type of starter is designed for specific application requirements. In addition to reducing starting torque, they also reduce inrush current and provide smoother acceleration of the pump.

Features

  • Heavy duty NEMA starter sizes 1 to 6 including Siemens exclusive half size starters to provide reliable motor control and protection expected in the most demanding applications
  • The ESP200 solid state overload relay has a protective coating on the circuit board which gives it superior protection against high humidity, condensation and corrosive environments
  • Adjustable starting time
  • CPT supplied as standard
  • Type 3/3R enclosure which is fully gasketed to ensure a dust tight and water tight seal
  • Rugged 30 mm H-O-A switch and start push button, which are standard features, meet type 3, 4, 12 and 13 specifications and are oil and dust tight for durability
  • Door is removable for ease of installation and maintenance
  • Factory and field modifications for custom applications
  • UL rated as service entrance equipment permitting equipment to be pole mounted and installed directly off of utility power lines

Specifications

GTIN: 00887621921521

UNSPSC: 39121521

Country of Origin: United States of America (the)

Type
Reduced Voltage
Operating Temperature
-4 to 104 deg F
Control Type
Start Pushbutton/Hand-Off-Auto Selector Switch
Auxiliary Contact Rating
10 A at 600 VAC (A600), 5 A at 600 VDC (P600)
Wattage
14 W
Timing
26 to 41 ms On/14 to 19 ms Off
Frequency Rating
50/60 Hz
Voltage Rating
460 VAC
Size
SZ 3
Weight
6 lbs
Enclosure Type
NEMA 3/3R/12
Dimensions
55 in H x 28 in W x 11 in D
Setting
315 to 1000 A
Motor Power
50 hp
Coil Voltage
24 VAC
Series
Class 88
Connection Type
Box Lug/Screw
Phase
3
Reset Type
Automatic/Manual/Remote
Amperage Rating
90 A
Operating Cycles
5000000 Cycles
Overload Relay
Solid-State
BABA Compliant
No
Sold as
EACH

Recently Viewed Products

Loading recently viewed products...

Reviews

Loading product reviews...
Loading product details...